Description: Punch drive motor error with 1-bin tray (D586) The machine does not detect a correct signal from the punch position sensor while the punch drive motor is operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Defective punch drive motor • Loosen connection • Motor overload • Defective punch position sensor
Remedy: 1. Replace the punch position sensor . 2. Replace the punch drive motor.