Mã lỗi 821 — Ricoh D140 MP2852

Code: 821

Description: Self-diagnostics error: ASIC
ASIC error
Causes: Defective ASIC device
Remedy: [0B00] ASIC error The write-&-verify check error has occurred in the ASIC. Defective ASIC device Replace the controller. [0B06] ASIC detection error The I/O ASIC for system control is not detected. Defective ASIC Defective North Bridge and PCI I/F Replace the controller board. [0D05] Self-diagnosis error: ASIC The CPU checks if the ASIC timer works correctly compared with the CPU timer. If the ASIC timer does not function in the specified range, this SC code is displayed. System firmware problem Defective RAM-DIMM Defective controller 1. Reinstall the controller system firmware. 2. Replace the RAM-DIMM. 3. Replace the controller board. [50A1] Video bridge device (ASIC) error 1 The CPU does not detect the video bridge device. Defective I/F between the video bridge device and controller Replace the controller. [50A2] Video bridge device (ASIC) register error 1 The CPU detects the video bridge device, but detects error data from the video bridge device. Defective I/F between the video bridge device and controller Replace the controller.