Code: 650
Description: Communication error of the remote service modem (Cumin-M)
Authentication error The authentication for the Cumin-M failed at dial up connection.
Authentication error The authentication for the Cumin-M failed at dial up connection.
Causes: -001 - Authentication error The authentication for the Cumin-M failed at dial up connection. • Incorrect SP settings • Disconnected telephone line • Disconnected modem board Check and set the correct user name (SP5816-156) and password (SP5816-157). -004 - Incorrect modem setting Dial up fails due to the incorrect modem setting. Same as -001 Check and set the correct AT command (SP5819-160). -005 - Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection. Same as -001 Consult with the user's local telephone company. -011 - Incorrect network setting Both the NIC and Cumin-M are activated at the same time. Same as -001 Disable the NIC with SP5985-1. -012 - Modem board error The modem board does not work properly even though the setting of the modem board is installed with a dial up connection. Same as -001 1. Install the modem board. 2. Replace the modem board.
Remedy: