Mã lỗi SC121 — Ricoh A257 Aficio Color 6010 Cattleya

Code: SC121

Description: Scanner HP sensor does not turn off - Timing & Condition - The sensor does not turn off when the scanner moves to the home position after scanning an original. The sensor output at CN403-A1 stays LOW (0V).
Causes: • Scanner motor out of synchronization (drive error) • Poor connection of connectors • Defective scanner HP sensor • Defective sub/main scanner IPU board • Defective main control board
Remedy: 1. In SP 5-804-104, stop supplying the current to the scanner motor. Check the output signal from the scanner H.P. sensor in SP 5-803-100 by moving the scanner manually. (0: Not actuated; 1: Actuated - at H.P.) 2. If the result of step 1 is OK; 1 Check the tension of the timing belt. 2 Check if the pulley is firmly secured. 3 Check if the scanner wire is properly wired 4 Check the connection of CN700, CN701, and CN702 on the scanner motor drive board. 5 Check continuity of harnesses. 6 Replace the scanner motor drive board. 7 Replace the scanner motor. 3. If the result of step 1 is not OK; 1 Check if the harness is properly connected. 2 Check the continuity of harness. 3 Replace the sensor. 4 Replace the sub and/or main scanner IPU board(s). 5 Replace the main control board. [ Signal Check ] • Scanner HP: CN403-A1 on sub scanner IPU board