Code: SC303
Description: Charge cleaner motor error - Timing - When the charge cleaner starts - Condition - • Over-current is detected for 10 seconds when the cleaner pads start moving from rear to front. • Over-current is still not detected 1 minute after the cleaner motor turns on.
Causes: • Poor connection of connector • Defective cleaner motor • Cleaner pad locked • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connectors (CN861 & CN829) are firmly connected. 2. Check if the charge corona unit is properly set. 3. Clean the screw shaft if it is dirty. 4. Check if the cleaner pad is mechanically locked. 5. Check if the connector is firmly connected on the I/O control board (CN219). 6. Replace the I/O control board. 7. Replace the main control board.