Code: SC455
Description: Paper transfer belt discharge corona current leak - Timing & Condition - When the current leak is detected for 2 seconds, leak detection starts 1 second after the discharge corona turns on. The leak signal is monitored twice at every 1 second. When the leak condition is detected twice continuously, this SC is displayed.
Causes: • Discharge unit not properly set • Corona wire broken • Defective high voltage supply board (Q2) • Defective I/O control board • Defective main control board
Remedy: 1. Check if the discharge corona unit is properly set. 2. Replace the discharge if it is broken. 3. Check if the connectors on the terminal and high voltage supply board (Q2) are properly connected and if the harnesses are damaged. 4. Clean the receptacle. 5. Replace the high voltage supply board (Q2). 6. Replace the I/O control board. 7. Replace the main control board. [ Signal Check ] • Leak detection: CN221-A5 or TP149 on I/O control board