Code: SC510
Description: Paper feed motor error - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal is sent. • The feedback signal becomes out of range for 2 seconds while the trigger signal is ON.
Causes: • Poor connection of connector • Defective paper feed motor • Defective I/O control board • Defective main control board • Mechanical overload
Remedy: 1. Check if the connector is properly connected on the I/O control board (CN230). 2. Replace the paper feed motor. (Output check: SP 5- 804-008 to 009) 3. Replace the I/O control board. 4. Replace the main control board. 5. Check the feed unit drive section and if anything causes overload. [ Signal Check ] • Motor OK: CN230-A1 or TP269 on I/O control board