Mã lỗi SC541 — Ricoh A257 Aficio Color 6010 Cattleya

Code: SC541

Description: Hot roller thermistor open - Timing - at every 1 second when the fusing unit is set - Condition - The hot roller thermistor output is almost close to 5V, which is correspond to 0°C, for 6 seconds continuously
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the fusing unit is properly set. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the attached Temperature/ Resistance Conversion Reference Table.) 5. Replace the I/O control board. 6. Replace the main control board. [ Signal Check ] • Thermistor: CN214-A4, TP234, or CN211-B1 on I/O control board / CN302-B9 or TP117 on main control board.