Code: SC552
Description: Pressure roller warm-up error - Timing & Condition - The pressure roller thermistor does not output an analog value corresponding to the ready temperature within 12 minutes after the main switch is turned on.
Causes: • Poor connection of connectors • Pressure roller fusing lamp brown • Pressure roller thermofuse opened • Brown fuse • Power fluctuation • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Check if the following connectors are properly connected; • Pressure roller fusing lamp connectors • CN303 on the main control board • CN212 and CN229 on the I/O control board • CN7 on the AC drive board 2. Replace the hot roller fusing lamp if it is opened. 3. Replace the hot roller thermofuse if it is opened. 4. Check if the power supplied from the outlet fluctuates. 5. Replace the main control board, I/O control board, or AC drive board by checking the trigger signal at each pin. [ Signal Check ] • Pressure roller fusing trigger: CN303-B7 on main control board / CN212-B5, TP240, or CN229-4 on I/O control board / CN7-7 on AC drive board.