Mã lỗi SC901 — Ricoh A257 Aficio Color 6010 Cattleya
Code:
SC901
Description: Upper total counter error (Black) - Timing & Condition - • Feedback signal stays LOW when the main switch is turned on. • Feedback signal stays LOW just before the trigger signal goes ON. • Feedback signal stays HIGH just before the trigger signal goes OFF.
Causes: • Poor connection of the connectors • Defective counter
Remedy: Check if the connectors are properly set. Replace the total counter. [ Signal Check ] Trigger line: CN230-B8 on I/O control board Counter OK signal: TP227 on I/O control Board