Mã lỗi SC101 — Ricoh A258 Aficio Color 3006 Iris

Code: SC101

Description: Exposure lamp failure - Timing & Condition - • The lamp output check signal (LAMPDET) is still HIGH 250 ms after the lamp turns on (the ON check is canceled if the lamp goes off within 250 ms). • The lamp output check signal is still LOW 30ms after the lamp turns off (the OFF check is canceled if the lamp turns on within 30 ms).
Causes: • Blown lamp • Blown thermostat • Blown fuse (FU103) • Defective lamp regulator • Poor connection of cables • Defective cables • Defective scanner IPU board • Defective PSU
Remedy: 1. Visually check the lamp element or check the continuity between both ends of the lamp terminals with a multimeter. 2. Check continuity at the ends of the thermostat terminals with a multi-meter. 3. Check if the connectors (CN1, CN2, and CN3) on the lamp regulator are properly connected. 4. Check the continuity of the 3 cables. 5. Replace the lamp regulator if 100Vac is present at the CN3-1 and 5 on the lamp regulator. 6. Replace the scanner IPU board - Signals to Check - • LAMPDET: CN502-2 on lamp regulator / CN403-12 on scanner IPU board • LAMPTRIG: CN403-11 on scanner IPU board / CN502- 3 on lamp regulator