Code: SC120
Description: Scanner HP sensor does not turn on - Timing & Condition - The scanner H.P. sensor does not turn on when the scanner moves back to the home position or at the home position check. The sensor output at CN406-7 stays HIGH (5V).
Causes: • Scanner motor out of synchronization (drive error) • Poor connection of connectors • Defective scanner HP sensor • Defective scanner IPU board • Defective main control board
Remedy: 1. In SP 5-804-104, stop supplying the current to the scanner motor. Check the output signal from the scanner H.P. sensor in SP 5-803-100 by moving the scanner manually. (0: Not actuated; 1: Actuated - at H.P.) 2. If the result of step 1 is OK; 1 Check the tension of the timing belt. 2 Check if the pulley is firmly secured. 3 Check if the scanner wire is properly wired 4 Check the connection of CN710, and CN731 on the scanner motor drive board. 5 Check continuity of cables. 6 Replace the scanner motor drive board. 7 Replace the scanner motor. 3. If the result of step 1 is not OK; 1 Check if the cable is properly connected. 2 Check the continuity of cable. 3 Replace the sensor. 4 Replace the scanner IPU board. 5 Replace the main control board. - Signals to Check - • Scanner HP: CN406-7 on scanner IPU board