Code: SC361
Description: Revolver HP sensor error - Timing & Condition - The home position is not detected during 3 revolutions of the revolver unit after the revolver motor turns on.
Causes: • Poor connection of connector • Dirty sensor • Defective sensor • Defective revolver motor • Defective revolver drive board • Defective I/O control board • Defective main control board
Remedy: 1. Check if the sensor connector is properly connected. 2. Replace the revolver H.P. sensor if the voltage at CN203-A4 on the I/O control board does not change when covering the sensor with a piece of paper. NOTE: Make sure that the revolver unit is locked for this step. 3. If the revolver unit does not rotate; 1 Replace the revolver motor. 2 Replace the revolver motor drive board. 3 Replace the I/O control board. 4 Replace the main control board. - Signals to Check - • Revolver H.P.: CN203-A4 or TP211 on I/O control board