Code: SC440
Description: Drum motor error - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal is sent. • The feedback signal becomes out of range for 2 seconds while the trigger signal is on.
Causes: • Poor connection of connector • Defective drum motor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the drum is locked by the cleaning blade. If it is, replace the cleaning blade. 2. Check if the connector (CN223) on the I/O control board is properly connected. 3. Check if the drum motor works properly using SP 5- 804-001 to 004. If not, replace the drum motor. 4. Replace the I/O control board. 5. Replace the main control board. - Signals to Check - • Motor OK: CN223-B5 or TP295 on the I/O control board