Code: SC450
Description: Paper transfer bias current error - Timing - When the paper transfer bias is on during printing - Condition - The feedback voltage is 4.8V or higher (indicating a leak), or PWM value is 50% or higher for 500 ms continuously.
Causes: • Defective high voltage supply (T2,D) • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connectors of high voltage cables and trigger lines are properly connected on the high voltage supply board (T2,D), I/O control board, and main control board. 2. Replace the high voltage supply board (T2,D). 3. Replace the I/O control board. 4. Replace the main control board. - Signals to Check - • Feedback signal: CN227-A3, TP220, or CN214-A3 on I/O control board / CN302-A7 or TP105 on the main control board • PWM: CN227-A4 or TP208 on I/O control board