Mã lỗi SC551 — Ricoh A258 Aficio Color 3006 Iris

Code: SC551

Description: Pressure roller thermistor open - Timing - Every 1 second after the fusing unit is installed - Condition - The pressure roller thermistor output is almost close to 5V, which corresponds to 0 °C, for 6 seconds continuously.
Causes: • Fusing unit not installed properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the fusing unit is properly installed. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the Temperature/ Resistance Conversion Reference Table at the end of this SC code table.) 5. Replace the I/O control board. 6. Replace the main control board. - Signals to Check - • Thermistor: CN206-B4, TP230, or CN214-B2 on I/O control board / CN302-B8 or TP156 on main control board.

← Xem tất cả mã lỗi Ricoh A258 Aficio Color 3006 Iris