Code: SC422
Description: PCC leak - Timing & Condition - When the current leak is detected for 2 seconds, leak detection starts 1 second after the PCC turns on. The leak signal is monitored twice at 1 second intervals. When the leak condition is detected twice continuously, this SC is displayed.
Causes: • PCC unit not properly set • Corona wire broken • Defective high voltage supply board (T1,PCC) • Defective I/O control board • Defective main control board
Remedy: 1. Check if the PCC unit is properly instaled. 2. Replace the corona wire if it is broken. 3. Check if the connectors on the terminal and high voltage supply board (T1,PCC) are properly connected and if the cables are damaged. 4. Clean the receptacle. 5. Replace the high voltage supply board (T1,PCC). 6. Replace the I/O control board. 7. Replace the main control board. - Signals to Check - • Leak detection: CN227-B1 or TP294 on I/O control board.