Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC545 — Ricoh A259 Aficio Color 4006 Lilac

Code: SC545

Description: Hot roller ready temperature abnormal - Timing - Every 1 second after the temperature reaches the ready condition - Condition - The hot roller thermistor output does not reach the ready temperature within 7 minutes.
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board • Defective PSU
Remedy: 1. Check if the fusing unit is properly instaled. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the Temperature/ Resistance Conversion Reference Table at the end of this SC code table.) 5. Replace the main control board, I/O control board, or PSU (check the output from the thermistor and the trigger signal at each pin). - Signals to Check - • Thermistor: CN206-B9, TP231, or CN214-B1 on I/O control board / CN302-B9 or TP154 on main control board. • Hot roller fusing trigger: CN303-B6 on main control board / CN205-A4, TP267, or CN218-B6 on I/O control board / CN106-5 on PSU.

← Xem tất cả mã lỗi Ricoh A259 Aficio Color 4006 Lilac

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie