Code: SC495
Description: Temperature sensor error - Timing & Condition - The temperature sensor output is out of range (2.75V or greater or less than 0.25V).
Causes: • Poor connection of connector • Defective humidity sensor • Defective I/O control board • Defective main control board
Remedy: 1. Check that the connectors (CN236, 214 & CN302) are properly connected on the I/O control board and main control board. 2. Replace the humidity sensor. 3. Replace the I/O control board. 4. Replace the main control board. - Signals to Check - • Temperature: CN236-6, TP247, or CN214-A9 on I/O control board / CN302-A1 or TP223 on main control board