Mã lỗi SC544 — Ricoh A260 Aficio Color 4106 Lilac

Code: SC544

Description: Hot roller fusing lamp lower limit temperature detected - Timing - Every 1 second after warm-up is completed - Condition - The hot roller thermistor output is higher than about 3V, which corresponds to 87 °C, for 8 seconds continuously after warm-up is completed.
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board • Defective PSU
Remedy: 1. Check if the fusing unit is properly instaled. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the Temperature/ Resistance Conversion Reference Table at the end of this SC code table.) 5. Replace the main control board, I/O control board, or PSU (check the output from the thermistor and the trigger signal at each pin). - Signals to Check - • Thermistor: CN206-B9, TP231, or CN214-B1 on I/O control board / CN302-B9 or TP154 on main control board. • Hot roller fusing trigger: CN303-B6 on main control board / CN205-A4, TP267, or CN218-B6 on I/O control board / CN106-5 on PSU.

← Xem tất cả mã lỗi Ricoh A260 Aficio Color 4106 Lilac