Mã lỗi SC554-02 — Ricoh D202 MP6054 Cor-C1
Code:
SC554-02
Description: Fusing End NC Sensor High Temperature Detection (hardware) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating edge thermopile defective • Fusing control software: out of control
Remedy: • Attach the new fusing unit, then run SP-5-810-002. • If necessary, replace the BCU or Fusing edge NC sensor.