Mã lỗi 835-00 — Ricoh D219 MPC306ZSP GR-C2

Code: 835-00

Description: Self-diagnostic error: Centronic device [xxxx]: Detailed error code.
Causes: [1102] Verify error The loopback connector is connected but check results is an error. • IEEE1284 connector error • Centronic loopback connector defective Replace the controller board. [110C] DMA verify error The loopback connector is connected but check results is an error. • ASIC device error • IEEE1284 connector error • Centronic loopback connector is defective Replace the controller board. [1120] Loopback connector not detected Centronic loopback connector is not connected for detailed self-diagnostic test. • Centronic loopback connector not connected correctly • Centronic loopback connector is defective • ASIC device is defective • Connect the centronic loopback connector • Replace the centronic loopback connector • Replace the controller board.
Remedy: