Description: LED intensity adjustment error The peak white level cannot be in the prescribed value even though adjusting several times. This SC is detected when the machine adjusts the LED’s light intensity.
Remedy: 1. Check if the SC occurs by turning the power off then on. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step. 2. Reconnect the following connectors. SBU-BiCU harness (FFC) connector SBU-LEDB harness (FFC) connector (SBU) 3. Check the white plate (Exposure glass). Replace the exposure glass, if dirty or damaged. 4. Replace the scanner carriage. 5. Replace the BiCU. 6. Replace the harness (FFC).