Code: SC301
Description: Charge current leak - Timing - When the main charge is ON in the printing process or process control mode - Condition - The current leak is detected for 2 seconds.
Causes: • Charge corona unit not installed properly • Poor connection of harnesses • Defective high voltage supply board (C/G/B) • Defective I/O control board • Defective main control board.
Remedy: 1. Reinstall the charge corona unit properly or replace the charge corona unit. 2. Reconnect the connectors on the high voltage supply board (C/G/B), I/O control board, and main control board, or check the harnesses. 3. Check and clean the charge corona unit receptacle. 4. Replace the high voltage supply board (C/G/B). 5. Replace the I/O control board. 6. Replace the main control board. [ Signal Check ] • Leak detection: CN217-7 or TP120 on I/O control board