Code: SC322
Description: Laser synchronizing signal error - Timing & Condition - While the polygon motor keeps running and LD is ON, the LD control board does not receive the laser synchronizing signal.
Causes: • Poor connection of connectors • Defective laser synchronizing detector board • Improper laser beam axis • Defective LD control board • Defective main control board • Defective optic housing unit
Remedy: 1. Check if the connectors (CN3 & CN 602) are properly connected on the laser synchronizing detector board and LD control board 2. Remove and clean the synchronizing detector board. 3. Check if anything such as seal of the Barrel Toroidal lens in the optic housing unit interferes the laser axis. 4. Replace the synchronizing detector board. 5. Check if the harness connectors (CN1 & CN603) on the LD unit and LD control board are properly connected or check the continuity of the harness. 6. Check if the harness connectors (CN604 & CN306) on the LD control board and main control board are properly connected or check the continuity of the harness. 7. Replace the LD control board. 8. Replace the main control board 9. Check the optical housing unit or replace it.