Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC360 — Ricoh A269 Aficio Color 6110 Cattleya

Code: SC360

Description: Development bias error - Timing - When the development DC bias turns ON during printing process or process control - Condition - The feedback voltage is 4.8V or higher, or PWM value becomes 80% or higher for 500 ms continuously.
Causes: • Poor connection of connectors • Dirty terminals • Defective high voltage supply (C/G/B) • Defective I/O control board • Defective main control board
Remedy: 1. Clean the development roller shaft (terminal) if it. 2. Clean the bias terminal if it is dirty. 3. Replace the bias terminal if it does not move smoothly. 4. Check the connectors of high voltage supply cable and trigger lines are properly connected on the high voltage supply board (C/G/B), I/O control board, and main control board. 5. Replace the high voltage supply board (C/G/B) 6. Replace the I/O control board. 7. Replace the main control board. [ Signal Check ] • Feedback signal: CN217-2, TP171, or CN211-A5 on I/O control board / CN302-A5 or TP111 on main control board • PWM: CN217-3 or TP141 on I/O control board