Mã lỗi 360-02 — Ricoh D236 MPC306 GR-C2

Code: 360-02

Description: TD sensor (Vt high) error 1: Cy • count is higher than the threshold which detects no developer • count is lower than the upper/lower target thresholds three consecutive times.
Causes: • TD sensor (mu sensor, sensor) failure • Harness loose or disconnected • An old PCDU may be installed
Remedy: 1. Check all the related connecters are connected. If not good, reconnect the connectors. Check if the SC reoccurs by cycling the power off/on. If the SC reoccurs, go to next step. 2. Check the development unit (e.g. Gear/harness disconnected? Heat protection seal removed? Using an old PCDU?). If not good, replace the development unit. If the SC reoccurs, go to the next step. 3. Check whether the TD sensor is deformed, scratched, damaged or has dust sticking to it. If not good, replace the PCDU. If the SC reoccurs, go to the next step. 4. Check the TD sensor harnesses, and the harness between the mainframe and PCDU. If not good, replace the harness. If the SC reoccurs, go to the next step. 5. Replace the BiCU.