Code: 361-04
Description: TD sensor (Vt) upper limit error 1: Ye. The machine detects that Vt (TD sensor output, SP3-210-001) is higher than the upper limit threshold (specified in SP3-211-002) for the specified consecutive times in SP3-211-003.
Causes: • TD sensor connector is disconnected
Remedy: To check if the issue is resolved: 1. Cycle the power off/on. 2. Feed one sheet of paper. 3. Check Vt with SP3-210-001 through -004. 4. Check if Vt is higher than the upper threshold (specified in SP3-211-002). Incorrect: Vt is higher than the upper threshold Correct: Vt is equal to or lower than the upper threshold Troubleshooting procedure: 1. Check all the connectors are firmly connected. If not, reconnect the connectors. Check if the SC reoccurs by cycling the power off/on. If the SC reoccurs, go to the next step. 2. Check the development unit (e.g. Gear/harness disconnected? Heat protection seal removed? Using an old PCDU?). If not good, replace the PCDU. If the SC reoccurs, go to the next step. 3. Check the TD sensor. If not good, replace the TD sensor. If the SC reoccurs, go to the next step. 4. Check the parameters (e.g. SP3-030-061 through -064 should be changed from its initial value, but could be not changed due to possible NVRAM clearing). If not good, replace the PCDU and initialize the developer. This corrects the TD sensor settings. 5. Check the toner supply unit, especially if the image density is too low. If the toner bottle is empty, the toner supply route is clogged, and/or the toner supply motor operates incorrectly, then correct the problem. If the SC reoccurs, go to the next step. 6. Check the harness connection. If not good, replace the harness between BiCU and PCDU. 7. Replace the BiCU.