Code: 370-00
Description: ID sensor calibration error The reflection light output voltage of the ID sensor (Vsg_reg) is not adjusted within the target range. Upper limit: SP3320-013 (default: 4.5 V) Lower limit: SP3320-014 (default: 3.5 V)
Causes: • Disconnected ID sensor connectors • Dirty or defective ID sensor • Defective image transfer belt
Remedy: To check if the issue is resolved: • Do Vsg adjustment (SP3-320). • Check the result in SP3-323-001. Correct: The result is “1” Incorrect: The result is not “1” Troubleshooting procedure: 1. Check all the connectors are firmly connected. If not, reconnect the connectors. Check if the SC reoccurs by cycling the power off/on. If the SC reoccurs, go to the next step. 2. Clean the detecting part of the ID sensor • Do not wipe with a dry cloth. (page 191 "Maintenance Tables") If the SC reoccurs, go to the next step. 3. Check the ID sensor shutter. If the shutter does not move correctly, replace the shutter solenoid. If the SC reoccurs, go to the next step. 4. Replace the drum and/or ITB if the following is found: Scratches, toner filming, wavy belt, or insufficient cleaning 5. Replace the ID sensor. If the SC reoccurs, go to the next step. 6. Check and connect the related harness if it is disconnected. 7. Replace the BiCU.