Causes: [0B00] ASIC register check error The write-&-verify check has occurred in the ASIC. Defective ASIC device Replace the controller board. [0B06] ASIC detection error Error in the I/O ASIC for system control detection • Defective ASIC • Defective North Bridge and PCII/F Replace the controller board. [0D05] Comparison error of CPU and ASIC timer The CPU checks if the ASIC timer works correctly compared with the CPU timer. If the ASIC timer does not function in the specified range, this SC code is displayed. • Defective ASIC timer device • Defective CPU device Replace the controller board. [50A1] Video bridge device detection error Video bridge device is not detected. • Video bridge device ASIC (HARP or KLAVIER) defective. • Connection error between PCI I / F of the controller ASIC and video bridge device ASIC. Replace the controller board [50A2] Video bridge device (ASIC) register error The CPU detects the video bridge device, but detects error data from the video bridge device. Defective I/F between the video bridge device and the controller Replace the controller board.