Code: SC543
Description: Hot roller fusing lamp overheat - Timing - at every 1 second when the fusing unit is set - Condition - The hot roller thermistor output is lower than about 0.3V, which is correspond to 220°C, for 3 seconds continuously.
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board • Defective AC drive board
Remedy: 1. Check if the fusing unit is properly set. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the attached Temperature/ Resistance Conversion Reference Table.) 5. Replace the main control board, I/O control board, or AC drive board by checking output from the thermistor and the trigger signal at each pin. [ Signal Check ] • Thermistor: CN214-A4, TP234, or CN211-B1 on I/O control board / CN302-B9 or TP117 on main control board. • Hot roller fusing trigger: CN303-B6 on main control board / CN212-B6, TP248, or CN229-5 on I/O control board / CN7-6 on AC drive board.