Code: SC557
Description: Pressure roller temperature does not increase - Timing - at every 1 second, 2minutes after the main switch turned on and before the hot roller temperature does not reach to the ready condition - Condition - The pressure roller temperature does not increase by no more than 3°C for a minutes during warm-up.
Causes: • Poor connection of connectors • Pressure roller fusing lamp brown • Pressure roller thermofuse opened • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Check if the following connectors are properly connected; • Hot roller fusing lamp connectors • CN303 on the main control board • CN212 and CN229 on the I/O control board • CN7 on the AC drive board 2. Replace the hot roller fusing lamp if it is opened. 3. Replace the hot roller thermofuse if it is opened. 4. Replace the main control board, I/O control board, or AC drive board by checking the trigger signal at each pin. [ Signal Check ] • Pressure roller fusing trigger: CN303-B7 on main control board / CN212-B5, TP240, or CNCN229-4 on I/O control board / CN7-7 on AC drive board.