Code: SC742
Description: LCT: Tray lift error - Timing & Condition - • The upper limit sensor does not activate within 18 seconds after the lift motor turns on (in UP direction) when the main switch is turned on or close the LCT cover. • The lower limit sensor does not activate within 18 seconds after the lift motor turns on (in DOWN direction) when paper runs out (paper end) or the Down key is pressed.
Causes: • Poor connection of connectors • Defective lift motor • Defective upper limit sensor • Defective pick-up solenoid • Defective LCT main board
Remedy: 1. Check if the connectors of the lift motor, upper limit sensor, and pick-up solenoid are properly connected. 2. Replace the lift motor. 3. Replace the upper limit sensor. 4. Replace the pick-up solenoid. 5. Replace the LCT main board