Mã lỗi SC554-01 — Ricoh D250 MP3054 Cor-C1
Code:
SC554-01
Description: Fusing End Thermopile High Temperature Detection (hardware) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating edge thermopile defective • Fusing control software: out of control
Remedy: • If the triac is defective, replace the AC power supply board. • If necessary, replace the BCU or heating edge thermopile.
← Xem tất cả mã lỗi Ricoh D250 MP3054 Cor-C1