Code: SC623-00
Description: Paper Bank Communication Error (D696) When two trays PFU (D787) and side LICT (D696) or LCIT (D695) and side LCIT (D696) are installed, 1. When the upper stream unit (D787 or D695) recognizes the lower stream unit (D696), the break of the lower stream unit is not canceled within predetermined milliseconds. 2. After the upper stream unit (D787 or D695) recognizes the lower stream unit (D696), there is no ACK within predetermined milliseconds after transmission of a data frame to the lower stream unit, and a timeout error occurs for 3 times consecutively even if retransmission is performed.
Causes: • Bank control board fault • Connector disconnected
Remedy: • Turn the power off/on. • Reset the optional paper tray connecting cable. • Replace the BCU. • Replace the optional paper tray.