Code: SC721-42
Description: Stapler Transfer Motor Error (1K sheet finisher) • During movement to home, the home position could not be detected within a predetermined pulse (p0 pulse) (1st time is jam notification, 2nd time is SC notification). • During movement from home, the home position was detected even after a predetermined pulse (p1 pulse) elapsed (1st time is jam notification, 2nd time is SC notification). • During movement from home, retreat sensor ON could not be detected even after a predetermined pulse (p2 pulse) elapsed (1st time is jam notification, 2nd time is SC notification). • During initialization, retreat sensor ON was detected simultaneously when the home position is detected (1st time is jam notification, 2nd time is SC notification). The return pulse to home and pulse coming from home during normal operation are calculated and measured. The pulses which are 1.5-2 times the normal operation pulse are taken as p0, p1 and p2.
Causes: • Motor defective • Connector disconnected • Overload • HP sensor defective • Retreat sensor error
Remedy: • Replace the stapler transfer motor • Reset the connector • Replace the stapler transfer HP sensor • Replace the harness • Replace the main board of the finisher