Code: SC370-00
Description: ID Sensor Calibration Error Regular reflection optical output voltage of the ID sensor: Vsg_reg cannot be adjusted to within target range. Upper limit (SP3-320-013: initial value 4.5V) Lower limit (SP3-320-014: initial value 3.5V)
Causes: • ID sensor connector missing/ connection fault • ID sensor detection window dirt • ID sensor malfunction
Remedy: • Check for ID sensor connector missing. If it is missing, reconnect it. • Check for dirt on the ID sensor detection window. If the detection window is dirty, clean by predetermined method (do not wipe dry). • If neither of the above have occurred, perform ID sensor replacement.