Code: SC835
Description: Self-diagnosis error: Centronics interface [XXXX]: Detailed error code [1102] Verification error The controller detects that the loop-back connector is not properly connected. [110C] DMA verification error A DMA data abnormality is detected even when the loopback connector is properly set. [1120] Loop-back connector error The loop-back connector is not set when starting the detailed self-diagnostics.
Causes: • Loose connection • Defective loop-back connector • Defective Centronics connector • Defective controller
Remedy: 1. Turn the main switch off and on. 2. Check the connection between the Centronics connector and loop-back connector. 3. Reconnect the loop-back connector. 4. Replace the controller.