Description: Finisher exit guide motor error Definition: [B] The exit guide plate open sensor or exit guide plate HP sensor does not activate within a certain time after the exit guide plate motor turned on.
Causes: · Exit guide motor defective · Exit guide plate HP sensor defective · Exit guide plate open sensor defective