Code: SC 672
Description: Controller-tooperation panel communication error at startup • After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with controller is interrupted after a normal startup. • After startup reset of the operation panel, the attention code or the attention acknowledge code is not sent from the controller. • After the controller issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
Causes: • Controller stalled • Controller board installed incorrectly • Controller board defective • Operation panel connector loose or defective
Remedy: 1. Turn the main switch off and on. 2. Check the condition of the controller board. 3. Check the condition of the operation panel. 4. Replace the controller board. 5. Replace the operation panel.