Code: 510
Description: LCT tray malfunction
One of the following conditions is detected: When the bottom plate is lifted, the upper limit sensor does not come on for 18 s. When the bottom plate is lowered, the lower limit sensor does not come on for 18 s. After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on. The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2.5 s, and a message prompts user to reset paper.
One of the following conditions is detected: When the bottom plate is lifted, the upper limit sensor does not come on for 18 s. When the bottom plate is lowered, the lower limit sensor does not come on for 18 s. After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on. The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2.5 s, and a message prompts user to reset paper.
Causes: • Tray lift motor defective or connector disconnected • Lift sensor defective or disconnected • Pick-up solenoid defective or disconnected • Paper end sensor defective