Code: 770
Description: Cover interposer tray bottom plate motor error
After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s). After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate.
After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s). After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate.
Causes: • Bottom plate position sensor, disconnected, defective • Bottom plate HP sensor disconnected, defective