Code: 204
Description: Polygon motor error: XSCRDY signal error
PMRDY_N signal consecutively detects that the polygon motor is an inactive state while LDB unit scans.
PMRDY_N signal consecutively detects that the polygon motor is an inactive state while LDB unit scans.
Causes: Disconnected cable from the polygon motor drive board or defective connection. Defective polygon motor or drive board
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.