Code: 210
Description: Trailing edge laser detection error: [K]
The laser synchronizing detection signal for LDB [K] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
The laser synchronizing detection signal for LDB [K] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector Defective LDB Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.