Code: 230
Description: FGATE ON error
The FGATE signal did not assert within 1 second. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
The FGATE signal did not assert within 1 second. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
Causes: Defective GAVD and PCI bridge ASIC. Defective BCU. Defective controller board. Defective harness between BCU and LDB.
Remedy: • Turn the Power Switch Off and On. • Connect the harness properly. • Replace the harness. • Replace LD unit. • Replace the controller board.