Code: 220
Description: Laser synchronization detection error: LD0
The laser synchronizing detection signal for the start position of the LD is not output within 500 ms after the LDB unit turns on with the polygon motor rotating normally.
The laser synchronizing detection signal for the start position of the LD is not output within 500 ms after the LDB unit turns on with the polygon motor rotating normally.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. efective laser synchronizing detector. Laser beam does not go into the photo detector. Defective GAVD. Defective LD Driver. Defective LDB. Defective BCU.
Remedy: • Turn the Power Switch Off and On.