Description: Main motor lock
The machine does not detect a main motor lock signal within 1 second after the main motor starts to rotate. -or- The machine does not detect a main motor lock signal for 250 ms continuously while the main motor is rotating.
The machine does not detect a main motor lock signal within 1 second after the main motor starts to rotate. -or- The machine does not detect a main motor lock signal for 250 ms continuously while the main motor is rotating.
Causes: Mechanical overload on the drive mechanism. Main motor defectivess.
Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the main motor.