Code: 543
Description: Fusing overheat error - software1
The detected temperature stays at 235°C for 1 second, and this consecutively occurs 10 times.
The detected temperature stays at 235°C for 1 second, and this consecutively occurs 10 times.
Causes: Defective Triac. Defective IOB. Defective engine board
Remedy: • Replace the Controller board. • This SC cannot be reset by turning the power off and on. • This SP should be reset by a CE. • SP5810-01 can reset this SC.