Code: 547
Description: Zero cross signal detection error
Zero cross signal is detected consecutively 4 times (for 200 ms) at power on with fusing relay being off. -or- Zero cross interrupts did not issue at the prescribed 3 second intervals. -or- The detection error occurs twice or more in 10 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Zero cross signal is detected consecutively 4 times (for 200 ms) at power on with fusing relay being off. -or- Zero cross interrupts did not issue at the prescribed 3 second intervals. -or- The detection error occurs twice or more in 10 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Causes: Defective fusing relay. Defective fusing relay circuit. Shorted +24V fuse on the PSU. Unstable AC power. AC line noise. As for an error due to a high frequency noise interference, this SC will not appear. In this case, SC557 will appear and output the log only.
Remedy: • Turn the Power Switch Off and On. • Replace the PSU.