Code: 995
Description: CPM setting error
Causes: -001 • Defective BICU Input the serial number with SP5811-004, and turn the main power switch off/on. -002 • Defective NVRAM on the controller • Defective controller 1. Install a new NVRAM, and turn off and on the main power switch after SC995-002 has occurred. 2. Reinstall the previous NVRAM or download the information with SP5825-001, after that turn the main power off and on. -003 • Incorrect type controller installed • Defective controller Replace the controller board with the correct type. -004 • Incorrect model controller installed. Replace the controller with the correct model.
Remedy: